Tissue Embedding SOP

Histopathology · Unimeditrek Pvt. Ltd.
⚠️ Validation required. This SOP template is provided for educational and quality-system support only. It is a starting point to adapt — not a validated procedure. Each laboratory must review, complete the lab-specific fields, validate and approve this SOP through its own pathologist / quality manager, and align it with local regulatory requirements before use.

1. Purpose

To cast firm, correctly-oriented paraffin blocks that section cleanly, presenting the diagnostically relevant tissue plane.

2. Scope

Applies to paraffin embedding of processed tissue at the embedding station. Excludes processing and microtomy.

3. Responsibility

4. Equipment & materials

5. Safety precautions

6. Procedure

Setup

  1. Confirm reservoir and cold-plate are at working temperature. Reservoir: [lab to validate]; cold plate: [lab to validate].
  2. Keep processed cassettes warm until embedded to prevent premature setting.

Embed

  1. Select the correct orientation for the tissue type (e.g. tubular/layered tissue on-edge to show all layers).
  2. Dispense molten paraffin into the mould, position tissue with warmed forceps, then transfer to the cold plate to set the orientation before topping up.
  3. Add the labelled cassette as the block base and top up with paraffin; allow to cool fully before removing.

7. Quality-control checkpoints

8. Acceptance criteria

9. Common errors & corrective action

ProblemCorrective action
Wrong orientationRe-embed on the correct plane; mark orientation at grossing; use an orientation reference at the station.
Air bubbles / voids in the blockEmbed with fully molten paraffin at the correct temperature; pour gently to avoid trapping air.
Tissue not flat / shifts before settingAllow the cold plate to set orientation before moving; verify cold-module temperature.

10. Records & documentation

11. Review frequency

Review at least annually or after a workflow/equipment change or recurring re-embedding.

12. Approval

RoleNameSignatureDate
Prepared by
Reviewed by (Quality Manager)
Approved by (Pathologist)